⚡ FIBC Products

Conductive Big Bag (Type C)

Type C FIBC bulk bags manufactured with antistatic and conductive yarn weave provide safe bulk material handling in combustible dust and explosive atmospheres (ATEX) environments.

IEC 61340-4-4ISO 9001:2015Type C Test Certificate
Conductive Big Bag (Type C)

Technical Specifications

Conductive Big Bag (Type C) Specs

Type Classification

Type C (Conductive)

Capacity

500 - 1500 kg

Safety Factor (SF)

5:1 or 6:1

Surface Resistance

< 10⁸ Ohm

Grounding

Grounding label + cable

Area of Use (ATEX Zones)

Dust: Zone 21, 22 · Gas: Zone 1, 2 (IIA/IIB)

Conductive Yarn Grid

20x20 mm or 50x50 mm

Fabric Color

Black yarn grid visible

Conductive Big Bag (Type C): Safety in Explosive Atmospheres

Type C Conductive Big Bag is a specialized FIBC designed for safe material handling in explosive atmospheres (ATEX).

Conductive yarns integrated into the fabric weave safely conduct static electricity to ground, preventing spark formation.

Static Electricity Hazard

Static electricity is generated by friction during filling or discharge operations.

Risk Factors

  • Static charge accumulates on standard big bag surfaces
  • Can discharge as a spark when reaching sufficient levels
  • Combustible dust (MIE < 1000 mJ) creates explosion risk
  • Explosive gas/vapor presence increases danger

Type C big bag eliminates this risk.

How Type C Works

Conductive Yarn Grid System

Type C big bag fabric contains conductive (carbon-content) yarns.

  • Grid spacing: 20x20 mm or 50x50 mm
  • Collects static charge from entire fabric surface
  • Yarns connected to grounding point

Grounding Mechanism

All conductive yarns connect to the grounding point (yellow-green labeled).

When connected to an effective grounding system, static electricity safely flows to ground.

Critical Usage Rules

⚠️ Grounding is Mandatory

Type C big bag MUST be used grounded.

  • Ungrounded use is extremely dangerous
  • Conductive yarns concentrate charge at one point
  • Without grounding, severe discharge occurs
  • More dangerous than standard big bag

Operational Rules

  • Continuous Connection — Grounding must remain active during entire operation
  • Visual Inspection — Check cable and connection before each use
  • Yarn Integrity — Verify no breaks or damage in conductive yarns

Use in Explosive Atmospheres (IEC 61340-4-4)

Our Type C big bags are tested to IEC 61340-4-4, the standard governing the electrostatic safety of FIBCs. Under this standard, Type C big bags are suitable, when properly grounded, for use in the following ATEX zones:

Suitable Zones

  • Zone 21 (explosive dust atmosphere likely)
  • Zone 22 (explosive dust atmosphere unlikely and short-lived)
  • Zones 1 and 2 (explosive gas atmosphere; gas groups IIA and IIB)

Product test certificate provided upon request.

Customization Options

Configure to Your Needs

Antistatic Liner

Surface resistance < 10⁹ Ohm PE liner

Conductive Liner

Conductive carbon-filled PE liner

Ground Label Position

Grounding point at top or bottom

Earth Cable

Integrated grounding cable

Screw Connection

Screw terminal for grounding

Application Areas

Where is Conductive Big Bag (Type C) Used?

✓ Chemical powders and fine particles
✓ Powder-form pharmaceutical raw materials
✓ Plastic granules (antistatic required)
✓ Food powders transported in explosive atmosphere
✓ Mineral and mining dusts
✓ Combustible organic dust products

Frequently Asked Questions

About Conductive Big Bag (Type C)

Type C (Conductive) Big Bag is an FIBC containing conductive yarns integrated into the fabric weave. These yarns conduct static electricity to the grounding point for safe discharge. Designed for safe use with combustible dusts or in explosive atmospheres (ATEX Zones 21-22 for dust, Zones 1-2 for gas groups IIA/IIB), it must always be grounded during use.

Type C big bag contains conductive yarns and MUST be grounded - cannot be used without grounding. Type D uses corona discharge technology and does not require grounding. Type C is more economical but requires operational discipline. Type D eliminates grounding oversight risk but has higher cost.

Conductive big bag is mandatory when: handling combustible dusts with Minimum Ignition Energy (MIE) < 1000 mJ, working in explosive gas/vapor environments, operating in areas classified as ATEX Zone 21/22 (dust) or Zone 1/2 (gas, IIA/IIB). Sugar, flour, aluminum powder, pharmaceutical active ingredients, and organic chemicals fall into this category.

The Type C big bag must be connected to an effective grounding system from its visible grounding label (yellow/green). Grounding resistance must be < 10⁸ Ohm. Grounding connection must be maintained throughout the ENTIRE filling and discharge operation. A big bag with broken or damaged grounding cable must never be used.

Type C big bags are tested according to IEC 61340-4-4 standard. Core tests include: fabric surface resistance test (< 10⁸ Ohm), conductive yarn continuity test, grounding point resistance test. Additionally, conductivity continuity of all seams and connection points is verified.

Related Industries

Which industries prefer this product?

Let's Get Started

Get in Touch For Your FIBC Needs

Request a Quote

Address

Cengeldere 107, 34830

Istanbul, Türkiye